Table of Contents
- DS2438
- Smart Battery Monitor
26 [.]XXXXXXXXXXXX[XX][/[ CA | EE | date | disconnect/date | disconnect/udate
| endcharge/date | endcharge/udate | IAD | offset | pages/page.[0-7|ALL] | temperature
| udate | VAD | VDD | vis | address | crc8 | id | locator | r_address
| r_id | r_locator | type ]]
26 [.]XXXXXXXXXXXX[XX][/[ HIH4000/humidity
| HTM1735/humidity | DATANAB/reset | DATANAB/humidity | humidity | temperature
]]
26 [.]XXXXXXXXXXXX[XX][/[ B1-R1-A/pressure | B1-R1-A/gain | B1-R1-A/offset
| ]]
26 [.]XXXXXXXXXXXX[XX][/[ S3-R1-A/current | S3-R1-A/illuminance | S3-R1-A/gain
]]
26
read-write,
binary
Memory is split into 8 pages of 8 bytes each. Only the pages 3-7 are really
available, and some of that appears to be reserved. See the datasheet for
details.
ALL is an aggregate of the pages. Each page is accessed sequentially.
read-only,
floating point
Temperature read by the chip at high resolution (~13 bits). Units are selected
from the invoking command line. See owfs(1)
or owhttpd(1)
for choices. Default
is Celsius. Conversion takes ~20 msec.
read-only, floating point
Voltage read (~10 bits) at the one of the chip’s two supply voltages. Range
VDD= 2.4V to 10V, VAD=1.5 to 10V.
read-only, floating point
Current sensor reading, as a voltage difference. Value is in volts.
Actual current depends on Rsens resistor (see datasheet).
The formula for current is I = vis / Rsens
with units in Amps and Ohms.
Current measurement will be temporarily enabled (see Ienable ) if not currently
enabled (pun intended) for this reading.
read-write,
yes-no
Current Accumulator Configuration flag bit. If "on" (1) current is stored
in page 7 bytes 4-7. If "off" (0) that page can be used for general storage.
See the datasheet for more information.
read-write, yes-no
Current Accumulator Shadow flag bit. If "on" (1) current reading is stored
to EEPROM. If "off" (0) that data will be lost when chip loses power. See
the datasheet for more information
read-write, yes-no
Current A/D Control flag bit. If "on" (1) current measured at 36.41 Hz. If
"off" (0) current measurements won’t be made. See the datasheet for more
information.
read-write, ascii
26 character date representation of the counter value. Increments once per
second.
Setting date to a null string will put the current system time.
Accepted date formats are:
Sat[urday] March 12 12:23:59 2001
Apr[il] 4 9:34:56 2002
3/23/04 23:34:57
current locale setting (your system’s format)
read-write, ascii
26 character date representation of the disconnect/udate value. Time when
the battery pack waws removed from the charger. Format is the same as the
date property.
read-write, unsigned integer
Representation of disconnect/date as a number. See udate for details.
read-write,
ascii
26 character date representation of the endcharge/udate value. Format is
the same as the date property.
read-write, unsigned integer
Representation of endcharge/date as a number. See udate for details.
read-write,
unsigned integer
Time represented as a number. udate increments once per second.
Usually set to unix time standard: number of seconds since Jan 1, 1970.
The date field will be the unix representation (ascii text) of udate and
setting either will change the other.
read-only,
floating point
Relative humidity, as percent (1-100 scale).
This value is for a design based on Honeywell’s HIH-4000 humidity sensor.
read-only, floating point
Relative humidity, as percent (1-100 scale).
This value is for a design based on Humirel’s HTM-1735 humidity sensor.
read-only,
floating point
Based on DataNAB’s humidity sensor. It uses a HIH-4000 sensor and the current
sensning rather than voltage readings from the DS2438. Calibration values
are stored on chip, and a check field is stored in chip memory.
write-only,
yes-no
Used to read calibration values and set the chip to current reading more.
Should be automatically called when a humidity reading is requested.
read-only,
floating point
Relative humidity, as percent (1-100 scale).
The DS2438 actually does not read humidity, but a widely available and
publicised circuit based on the chip, does. This design is for the common
Honeywell HIH-3610 humidity chip. The mostly compatible HIH-4000 chip uses
different temperature compensation, so is better read from the HIH4000/humidity
value. See the datasheets for details.
If the chip is instead a DATANAB design, the DATANAB/humidity value will
be automatically used.
read-only, floating
point
Pressure reading, as milli-bars, or other unit depending on settings/units/pressure_scale.
This value is for the B1-R1-A barometer from Hobby-Boards, and assumes the
standard calibration.
read/write, floating point
Calibration of pressure gain, as signed number, expressed as the same units
as B1-R1-A/pressure per volt.
This value will be multiplied with the measured voltage to get the B1-R1-A/pressure
reading. It may have to be fine tuned for calibration purposes, although
with the standard sensor, it will often be good enough to keep it as is.
read/write, floating point
Calibration of pressure offset, as signed number, same units as B1-R1-A/pressure.
This value will be added to the B1-R1-A/pressure reading. The default value
is 904.7 millibars, which may be altered to to compensate for elevation.
read-only, floating point
Photo-diode current, in micro-amperes.
This value is for the S3-R1-A solar radiation sensor from Hobby-Boards. Due
to noise and offsets, this value may read as a negative number in low light
conditions. The offset register can be modified to reduce the offset as
much as possible.
read-only, floating point
Illumination, in lux. Always a positive number.
This value is the lux reading from the solar sensor, taking S3-R1-A/gain
into consideration.
read/write, floating point
Calibration of photo-diode gain expressed as lux per micro-amperes. The default
value is for the SFH203P photo-diode from Osram, used bare. A different gain
may be used for instance to compensate for an integrathing, white sphere
placed over the diode.
This value is for the S3-R1-A solar radiation sensor from Hobby-Boards, using
the SFH203P photo-diode from Osram.
read-only,
ascii
For iButtonLink’s MultiSensor line of 1-wire devices, give the specific configuration
based on a data byte set in memory. (Byte 0 of page 3). This can help interpretation
of the sensor values, distinguishing, current from water from light.
read-write,
integer
Correction for current readings. A value between -256 and 255. See the datasheet
for details. Should be set to the negative of a true zero current reading.
read-only, ascii
The entire 64-bit unique ID. Given as upper case hexidecimal digits (0-9A-F).
address starts with the family code
r address is the address in reverse order, which is often used in other
applications and labeling.
read-only, ascii
The 8-bit error correction portion. Uses cyclic redundancy check. Computed
from the preceding 56 bits of the unique ID number. Given as upper case
hexidecimal digits (0-9A-F).
read-only, ascii
The 8-bit family code. Unique to each type of device. Given as upper case
hexidecimal digits (0-9A-F).
read-only, ascii
The 48-bit middle portion of the unique ID number. Does not include the family
code or CRC. Given as upper case hexidecimal digits (0-9A-F).
r id is the id in reverse order, which is often used in other applications
and labeling.
read-only, ascii
Uses an extension of the 1-wire design from iButtonLink company that associated
1-wire physical connections with a unique 1-wire code. If the connection is
behind a Link Locator the locator will show a unique 8-byte number (16 character
hexidecimal) starting with family code FE.
If no Link Locator is between the device and the master, the locator field
will be all FF.
r locator is the locator in reverse order.
read-only,
yes-no
Is the device currently present on the 1-wire bus?
read-only, ascii
Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton
vs chip) will not be distiguished.
None.
1-wire
is a wiring protocol and series of devices designed and manufactured by
Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme
where the data line can also provide power.
Each device is uniquely and
unalterably numbered during manufacture. There are a wide variety of devices,
including memory, sensors (humidity, temperature, voltage, contact, current),
switches, timers and data loggers. More complex devices (like thermocouple
sensors) can be built with these basic devices. There are also 1-wire devices
that have encryption included.
The 1-wire scheme uses a single bus master
and multiple slaves on the same wire. The bus master initiates all communication.
The slaves can be individually discovered and addressed using their unique
ID.
Bus masters come in a variety of configurations including serial, parallel,
i2c, network or USB adapters.
OWFS is a suite of programs that
designed to make the 1-wire bus and its devices easily accessible. The underlying
priciple is to create a virtual filesystem, with the unique ID being the
directory, and the individual properties of the device are represented
as simple files that can be read and written.
Details of the individual
slave or master design are hidden behind a consistent interface. The goal
is to provide an easy set of tools for a software designer to create monitoring
or control applications. There are some performance enhancements in the
implementation, including data caching, parallel access to bus masters,
and aggregation of device communication. Still the fundemental goal has
been ease of use, flexibility and correctness rather than speed.
The
DS2438 (3)
is a more complete form of the DS2436 battery chip. Current sensing
is available, but not implemented. The major advantage compared to the DS2436
is that two voltages can be read, allowing one to correct circuit measurements
for supply voltage and temperature. A better comparison is the DS276x family
of chips.
All 1-wire devices are factory assigned a unique
64-bit address. This address is of the form:
- Family Code
- 8 bits
- Address
- 48
bits
- CRC
- 8 bits
- Addressing under OWFS is in hexidecimal, of form:
- 01.123456789ABC
where 01 is an example 8-bit family code, and 12345678ABC is an example
48 bit address.
The dot is optional, and the CRC code can included. If included,
it must be correct.
http://pdfserv.maxim-ic.com/en/ds/DS2438.pdf
http://pdfserv.maxim-ic.com/en/an/humsensor.pdf
http://goo.gl/o9DH0 (Redirects to 009012_2.pdf PDF file on honeywell.com website)
http://www.phanderson.com/hih-4000.pdf
http://www.humirel.com/product/fichier/HTM1735%20RevG%20.pdf
owfs
(1)
owhttpd (1)
owftpd (1)
owserver (1)
owdir (1)
owread (1)
owwrite (1)
owpresent (1)
owtap (1)
owfs (5)
owtap (1)
owmon
(1)
owtcl (3)
owperl (3)
owcapi (3)
DS1427 (3)
DS1904(3)
DS1994 (3)
DS2404 (3)
DS2404S (3)
DS2415 (3)
DS2417 (3)
DS2401 (3)
DS2411
(3)
DS1990A (3)
DS1982 (3)
DS1985 (3)
DS1986 (3)
DS1991 (3)
DS1992
(3)
DS1993 (3)
DS1995 (3)
DS1996 (3)
DS2430A (3)
DS2431 (3)
DS2433 (3)
DS2502 (3)
DS2506 (3)
DS28E04 (3)
DS28EC20 (3)
DS2405 (3)
DS2406
(3)
DS2408 (3)
DS2409 (3)
DS2413 (3)
DS28EA00 (3)
DS1822 (3)
DS1825 (3)
DS1820 (3)
DS18B20 (3)
DS18S20 (3)
DS1920 (3)
DS1921 (3)
DS1821
(3)
DS28EA00 (3)
DS28E04 (3)
EDS0064 (3)
EDS0065 (3)
EDS0066 (3)
EDS0067
(3)
EDS0068 (3)
EDS0071 (3)
EDS0072 (3)
MAX31826 (3)
DS1922 (3)
DS2438 (3)
EDS0065 (3)
EDS0068 (3)
DS2450 (3)
DS2890 (3)
DS2436 (3)
DS2437 (3)
DS2438
(3)
DS2751 (3)
DS2755 (3)
DS2756 (3)
DS2760 (3)
DS2770 (3)
DS2780 (3)
DS2781
(3)
DS2788 (3)
DS2784 (3)
DS2423 (3)
LCD (3)
DS2408 (3)
DS1977 (3)
DS2406 (3)
TAI8570 EDS0066 (3)
EDS0068 (3)
EEEF
(3)
DS2438 (3)
http://www.owfs.org
Paul Alfille (paul.alfille@gmail.com)
Egil Kvaleberg
Table of Contents